The FLIR A400/A700 Thermal Smart Sensor Camera has the features that automation solution providers need for complex monitoring applications, including elevated skin temperature screening when used as an adjunct to other body temperature screening tools, critical infrastructure, product quality, and early fire detection. The Smart Sensor configuration includes multiple measurement tools and alarms while also providing computing-on-the-edge, with analytics performed at the camera level for immediate results. With a range of lens choices, motorized focus control, and unrivaled connectivity, A400/A700 cameras offer unmatched power and flexibility. Easy configuration allows you to tailor this monitoring system to your company’s quality, productivity, maintenance, and safety needs.
FLIR A400/A700 SMART THERMAL SENSOR
FLIR A400/A700 SMART THERMAL SENSOR
FLIR A400/A700 SMART THERMAL SENSOR
Speed Up Decision-Making, Reduce Downtime, Improve Product Quality
FLEXIBLE MEASUREMENT FEATURES FOR A WIDE RANGE OF APPLICATIONS
Includes options to adjust measurements and alarms based on a reference temperature source (advanced)
ADVANCED ANALYTICS FOR IMPROVED DECISIONS SUPPORT
Edge analytics with features such as a polygon function (advanced) help you make immediate, informed decisions
WORLD-CLASS THERMAL IMAGING
Provides exceptional image quality with up to 640 × 480 (307,200 pixels) and superior measurement accuracy (<±2°C)
SPECIFICATIONS
GENERAL | |
Contrast Enhancement |
FSX® / Histogram equalization (IR only) |
OVERVIEW |
|
Accuracy |
±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F) |
Alarm Functions |
On any selected measurement function, digital in, and internal camera temperature |
Alarm Output |
• Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • Store image or video |
Base Mounting |
4× M4 on 4 sides |
Encoding |
H.264, MPEG4, or MJPEG |
Housing Material |
Aluminium |
IR Resolution |
320 × 240 |
Object Temperature Range |
-20°C to 120°C (-4°F to 248°F), 0°C to 650°C (32°F to 1202°F), 300°C to 2000°C (572°F to 3632°F) |
Size (L x W x H) |
123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in) |
Thermal Sensitivity/NETD |
Lens dependent |
Web Interface |
Yes |
Weight |
0.82 kg (1.8 lb), camera only |
Multi-Streaming |
Yes |
CONNECTIONS & COMMUNICATIONS |
|
Digital I/O Connector Type |
M12 12-pin A-coded, Male (shared with external power) |
Digital I/O Isolation Voltage |
500 VRMS |
Digital Input Purpose |
NUC, NUC disable, alarm |
Digital Inputs |
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 v |
Digital Output Purpose |
• As a function of alarm, output to external device • Fault (NC) |
Digital Outputs |
3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
Ethernet |
For control, result, image, and power |
Ethernet Communication |
TCP/IP socket-based FLIR proprietary |
Ethernet Connector Type |
M12 8-pin X-coded, female; RP-SMA, female |
Ethernet Power |
Power over Ethernet, PoE IEEE 802.3af class 3 |
Ethernet Protocols |
• EtherNet/IP • IEEE 1588 • Modbus TCP Slave • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP |
Ethernet Standard |
IEEE 802.3 |
Ethernet Type |
1000 Mbps |
RS-232 |
NA |
WIFI |
Optional feature purchased separately. RP-SMA, female connector |
Ethernet Interface |
Wired, Wi-Fi (optional) |
Multicast |
Yes |
ENVIROMENTAL |
|
Atmospheric Transmission Correction |
Based on inputs of distance, atmospheric temperature, and relative humidity |
EMC |
• ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery) |
Emissivity Correction |
Variable from 0.01 to 1.0 |
Encapsulation |
IEC 60529, IP 54, IP66 with accessory |
Humidity (Operating and Storage) |
IEC 60068-2-30/24 hours, 95% relative humidity, 25°C–40°C (77°F–104°F)/2 cycles |
Operating Temperature Range |
-20°C to 50°C (–4°F to 122°F): • -20°C to 40°C (-4°F to 104°F) (in free air) • 40°C to 50°C (104°F to 122°F) (mounted on cooling plate accessory) Maximum camera case temperature: 65°C (149°F) |
Radio Spectrum |
• FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU) |
Shock |
IEC 60068-2-27, 25 g |
Tripod Mounting |
UNC ¼″-20 on 2 sides |
Vibration |
• IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway) |
Corrosion |
• ISO 12944 C4 G or H • EN60068-2-11 |
FILE STORAGE & DATA TRANSFER |
|
Video Storage |
Records up to 10 H.264 videos; storage as function of alarm — 5 sec. before alarm and 5 sec. after alarm. |
IMAGING & OPTICAL |
|
Available Lenses |
6°, 24°, 14°, 42° |
Detector Pitch |
24 µm |
Focal Plane Array (FPA) |
Uncooled microbolometer |
Focus |
One-shot contrast, motorized, and manual |
Image Frequency |
30 Hz |
Radiometric IR video streaming |
NA |
Readout |
Measurement results: • Ethernet/IP (pull) • Modbus TCP slave (pull) • MQTT (push) • Query over REST API (pull) • Measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), read access only • Web interface |
Spectral Range |
7.5–14 µm |
Streaming Resolution |
Video stream 0: 640 × 480 pixels Video stream 1: 1280 × 960 pixels |
Video Streaming |
RTSP protocol |
Overlay |
With / Without |
Visible Camera |
Optional accessory |
MEASUREMENT & ANALYSIS |
|
External Optics & Windows Correction |
Based on input of optics/window transmission and temperature |
Measurement Corrections |
Global object parameters; local parameters per analyze function |
Measurement Presets |
Yes |
Reflected Apparent Temperature Correction |
Based on input of reflected temperature |
Measurement Tools |
0 spotmeters, 10 boxes, 3 Deltas (difference any value/reference/external lock), 1 isotherm (above/below/interval), 1 iso-coverage, 1 reference temperature |
Automatic Hot & Cold Detection |
Max./min. temperature value and position shown within box |
POWER |
|
External Power Operation |
24/48 V DC 8 W max |
Power Connection |
M12 12-pin A-coded, male (shared with Digital I/O) |
Power Consumption |
• 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical |
External Voltage |
Allowed range 18–56 V DC |
RADIOMETERY |
|
Image Source |
Video stream 0: visual / IR / MSX® (visual camera is an optional feature) Video stream 1: visual |
STORAGE MEDIA |
|
Image Storage |
Records up to 100 FLIR radiometric JPEG; storage as function of: alarm, scheduling, or user interaction (camera web) |